PT - JOURNAL ARTICLE AU - Sleger, Vladimir AU - Mizera, Cestmir TI - Comparison of the Continuous and Intermittent Relaxation Test DP - 2015 Apr 1 TA - Manufacturing Technology Journal PG - 210--214 VI - 15 IP - 2 AID - 10.21062/ujep/x.2015/a/1213-2489/MT/15/2/210 IS - 12132489 AB - The article presents the measurement results of the relaxation of long-term loaded compression springs manufactured out of non-alloy steel. The goal was to determine the differences between the interrupted and uninterrupted tests. During the relaxation test that lasted 5000 hr in a laboratory with a temperature of 22ÂșC, initial shear stress set at a value of 30% of the ultimate tensile strength of the material, decreased the strength of the springs with a wire diameter of 1 mm by 3.6%, springs with a wire diameter of 3.15 mm by 2.5%, and springs with a wire diameter of 5 mm by 1.3%. The difference in the results was found in tests 16 times and 4 times interrupted to measure the current relaxation. The results of intermittent tests cannot be considered as relaxation values for statically loaded springs. Conversely, when determining the maximum tension of quasi-statically loaded springs with respect to the relaxation, the uninterrupted relaxation tests cannot be used.