RT Journal Article SR Electronic A1 Macháček, Pavel A1 Dvořák, Rudolf T1 A 3D Laser Scanner Setup for a Measuring of Geometrical Product Specifications JF Manufacturing Technology Journal YR 2015 VO 15 IS 5 SP 875 OP 881 DO 10.21062/ujep/x.2015/a/1213-2489/MT/15/5/875 UL https://journalmt.com/artkey/mft-201505-0025.php AB The laser line scanners are coming to be frequently used in a field of dimensional inspection process. There are several phenomena that make the data acquisition more difficult. Particularly secondary reflection, direct reflection, scan overlapping, outlying points. The effect of these phenomena can be minimised by optimal setting of scanning parameters stated in this paper. The parameters were determined from an experimental measurements of 50 various parts. Additionally a thermal stability effect was measured at two types of Nikon scanners. The stabilisation time and the systematic error were determined for the scanner LC15Dx: 45 min, 20μm and 30 min and 37 μm for the LC60Dx scanner. It should help to prevent the systematic errors during the measurement.