Manufacturing Technology 2016, 16(3):502-506 | DOI: 10.21062/ujep/x.2016/a/1213-2489/MT/16/3/502

Application of Lubrication into the Hip Joint Replacement

Andrea Haringová, Karol Stračár, Karol Prikkel
Faculty of Mechanical Engineering STU in Bratislava, Námestie Slobody 17, 812 31 Bratislava 1, Slovak Republic

The article deals with application of knowledge from lubrication of healthy spherical joints into hip joint endoprosthesis. As the observed most important physical parameter it was selected the coefficient of friction responsible directly for lifetime of the endoprosthesis. The article describes as well as experimentally verifies the idea of additional lubrication of hip joint endoprosthesis.

Keywords: lubrication, coefficient of friction, endoprosthesis

Published: June 1, 2016  Show citation

ACS AIP APA ASA Harvard Chicago IEEE ISO690 MLA NLM Turabian Vancouver
Haringová A, Stračár K, Prikkel K. Application of Lubrication into the Hip Joint Replacement. Manufacturing Technology. 2016;16(3):502-506. doi: 10.21062/ujep/x.2016/a/1213-2489/MT/16/3/502.
Download citation

References

  1. MEDLEY, J. B. (1981). The lubrication of normal human ankle joints, pp. 443, Department of Mechanical Engineering, The University of Leeds, England.
  2. WIERZCHOLSKI, K. (2010). Friction force and pressure calculation for time dependent impulsive intelligent lubrication of human hip joint, In Acta of bioengineering and biomechanics, Vol. 12, No. 3.
  3. HARINGOVÁ, A. - PRIKKEL, K. (2013). The designing of stand for testing of hip joint endoprosthesis, In: ERIN Journal of Slovak University of Technology, ISSN 1337-9089.
  4. HARINGOVÁ, A. - PRIKKEL, K. (2012). Effective thickness of synovial fluid layer in the gap of endoprosthesis of hip joint, pp. 4, In: Hydraulika a pneumatika, ISSN 1335-5171, vol. 12, No. 1-2.
  5. PRIKKEL, K - HARINGOVÁ, A. (2013). Endoprotéza kĺbu, najmä bedrového kĺbu, Číslo úľitkového vzoru: 6377 SK, 6376 SK, Vestník ÚPV SR, Vol. 13, No. 2.
  6. HART, R. - ROZKYDAL, Z. (1999). Dlouhodobé výsledky totální endoprotézy kycelního kloubu Poldi, pp. 139 - 145, In: Acta Chirurgiae orthopaedicae et Traumatologicae Cechoslovaca, No. 66.
  7. GALLO, J., HAVRÁNEK, V., ZAPLETALOVÁ, J., MANDÁT, D. (2006). Merení oteru polyetylenových jamek TEP kycelního kloubu univerzálním mericím mikroskopem, pp. 28 - 33, In Acta Chirurgiae orthopaedicae et Traumatologicae Cechoslovaca, No. 73. Go to original source...
  8. SEEBECK, P. (2009). Clinical and Technical Review: Hyaluronic acid (Hyaluronan), pp.24, TECOmedical Group.
  9. YUAN, L. (2004). Numerical study of multiple periodic flow states in spherical Couette flow, pp.81-91, ICMES &LSEC, Chinese Academy of Sciences, ISSN 1006-9283. Go to original source...
  10. ISO 14242-1:2012. Implants for surgery.
  11. ISO 7206-1:2008. Implants for surgery - Partial and total hip jointprostheses.
  12. PELAGIĆ, Z., NÁGEĄ, M., ®MINDÁK, M., RIECKY, D. (2015). Wear Simulation Modeling by Using the Finite Element Method, pp.191-195, In: Manufacturing technology, Vol. 15, No. 2. Go to original source...
  13. SEDLAK, J, SLANY, M, FIALA, Z, JAROS, A, BLAZKOVA, V. (2015). Testing of Implant Prototype of Femoral Component Using Hydraulic Machine ZD40, pp.416-423, In: Manufacturing technology, Vol. 15, No. 3. Go to original source...
  14. CIESLAR, J., BRO®EK, M., BEDNÁŘ, B. (2013). An Experimental Assessment of Special Metal Castings in Reducing Abrasive Wear, pp.423-428, In: Manufacturing technology, Vol. 13, No. 4. Go to original source...
  15. GALANIS, N.I., MARKOPOULOS, A.P., GIANNAKOPOULOS, I.D., MANOLAKOS, D.E. (2013). Manufacturing of Femoral Heads from Ti-6Al-4V Alloy with High Speed Machining: 3D Finite Element Modelling and Experimental Validation, pp.437-444, In: Manufacturing technology, Vol. 13, No. 4. Go to original source...
  16. BAKALOVA, T, LOUDA, P., VOLESKÝ, L., ANDR©OVÁ, Z. (2014) The Use of Optical Microscopy to Evaluate the Tribological Properties, pp. 256-261, In: Manufacturing technology, Vol. 14, No. 3. Go to original source...